Common questions

“Connection refused” or the scanner finds nothing

Check that your iPhone or iPad is on the same network as the device and that the Modbus TCP port (usually 502) is correct.

Modbus Field also needs Local Network access: Settings › Privacy & Security › Local Network › Modbus Field.

Values look wrong (huge or tiny numbers)

Edit the register block and try another byte order. Many devices use CDAB (word swap) for 32-bit values. The Register Converter in Tools shows a value in every byte order at once.

The address is off by one

Modbus documents mix 0-based offsets and 1-based register numbers. Change Settings › Address notation, or use Tools › Address Converter to translate 40001-style addresses.

A device behind a gateway does not answer

Use the RS485 slave address of the device as the Unit ID. With Pro, Scanner › Find Unit IDs lists every unit ID that answers behind the gateway.

Restore my Pro purchase

Open Settings › Restore Purchases while signed in with the same Apple ID you used to buy Pro. Pro is a one-time purchase and works on all your devices with that Apple ID.

Request a device profile

Send us the manufacturer, model and a link to the Modbus register map. You can also import your own profile as JSON in the Profiles tab.

Is it safe to write to my equipment?

Writing coils and registers can start, stop or change real equipment. Only write to devices you are authorised to operate and follow your site's safety procedures. Modbus TCP has no encryption or authentication, so use it only on trusted networks.